Enable/Disable Time Delay, set the Time Delay Period, and set the Confirmation Window on a 702 non-Display Keypad in LA GARD 700 Series Lock

Updated Apr 29, 2026

Question

How to Enable/Disable Time Delay, set the Time Delay Period, and set the Confirmation Window on a 702 non-Display Keypad in LA GARD 700 Series Lock?

Answer

During a Time Delay, the safe lock cannot be opened until the delay period expires. The Time Delay period ranges from 00 (Disabled) to 99 minutes and can be set either via the Keypad or through the LA GARD Software client. Once the Time Delay period is complete, the Confirmation Window period starts. During the confirmation period, the user can re-authenticate to open the lock. 

  • Keypads will provide continuous feedback to signify the Delay Period and Confirmation Window.
  • The Keypad will beep and flash a red LED once every 10 seconds during the Time Delay period.
  • The Keypad will then beep and flash a green LED once every 10 seconds during the Confirmation Window, signifying the safe lock can now be opened.
  • Display Keypads provide additional on-screen feedback during the Delay Period and Confirmation Window.
  • There are multiple ways to override the Time Delay period, if enabled. If Time Delay is enabled for a lock, each valid User ID with a Combination will trigger the start of the time delay period if the intent is to open the lock.

Follow these steps to Enable/Disable Time Delay on a Display Keypad:

  1. Using the Keypad, input #72 + Authorized ID and Combination + Delay Period (00 to 99 minutes) + Confirmation Window (01 to 60 minutes) + <return key> (←).
  2. The Keypad will beep three times and flash a green LED once complete.