Answer
During a Time Delay, the safe lock cannot be opened until the delay period expires. The Time Delay period ranges from 00 (Disabled) to 99 minutes and can be set either via the Keypad or through the LA GARD Software client. Once the Time Delay period is complete, the Confirmation Window period starts. During the confirmation period, the user can re-authenticate to open the lock.
- Keypads will provide continuous feedback to signify the Delay Period and Confirmation Window.
- The Keypad will beep and flash a red LED once every 10 seconds during the Time Delay period.
- The Keypad will then beep and flash a green LED once every 10 seconds during the Confirmation Window, signifying the safe lock can now be opened.
- Display Keypads provide additional on-screen feedback during the Delay Period and Confirmation Window.
- There are multiple ways to override the Time Delay period, if enabled. If Time Delay is enabled for a lock, each valid User ID with a Combination will trigger the start of the time delay period if the intent is to open the lock.
For Keypads with a display, there is an option to configure the time display for their respective time delay feature. Select one of the following options:
- Off.
- Count Up.
- Count Down
Follow these steps to set the options:
- Enter an Authorized User ID and Combination.
- Navigate through the Main Menu and select “System”.
- Select “TD Cnt Mode” from the sub-menu.
- Select either “Delay Period” or “Confirm Window”.
- Select one of the following choices and press the <return key> (←):
- “Off”
The time remaining or accumulated will not display; only information on what period it is in will be displayed
- Count Up
The count will start from 00:00 and count up until the period expires
- Count Down
The time will start at the period length and count down to 00:00
- “Success Mode Updated” appears on screen and the Keypad will beep three times and flash a green LED once complete.
|