The function Maximum Open Period allows you to determine how long the door can remain open until a forced closure is triggered. As soon as the Maximum Open Period has elapsed, an intermittent beep sounds when the door locks are open until the system is secured (boltwork closes). 

Maximum Open Period Details

  •  Setting range of Maximum Open Period [mm:ss]:
    - 00:00 Maximum Open Period disabled
    - 00:01 to 99:59 1 second to 99 minutes and 59 seconds
  • On delivery, the Maximum Open Period is disabled (setting “00:00”)
  • The Maximum Open Period is available only in the settings for lock 1 and is valid for the entire locking system.
  • The setting is taken over with the next opening only. 
  • The Maximum Open Period does not apply to the inner compartment locks. 

Authorization & Requirements

  • Authorization: Master Code “MA1”, Time Code “TC1” 
  • Requirement: System status “Unlocked” (door locks and door bolt open) 

Procedure: Setting the Maximum Open Period

To set the Maximum Open Period, proceed as follows:

1. Wake up display (if necessary) and access menu.

Lock display showing system status “Unlocked” with date and time, indicating the system is ready for configuration.

2. Select and confirm the menu option “Settings”.

Main menu screen with the “Settings” option highlighted on the Paxos lock display.

3. Select and confirm menu option “Settings Lock 1”.

Settings menu showing “Lock 1” selected.

4. Enter and confirm Master Code of lock 1.

Lock display prompting for “Code Lock 1 (MA, TC),” indicating that the master code and time code are required.

5. If the function Maximum Open Period is disabled, select and confirm the menu option “Settings L1 Other”.

Lock display showing masked entry of the master code and time code for authorization.

6. Select and confirm menu option “Other L1 Max. Open Period” or “Settings S1 Max. Open Period”.

7. Enter and confirm desired Maximum Open Period (format: mm.ss).
Note: If you want to disable the maximum opening period, enter “00.00”.

Menu screen displaying the “Max. Door Open” or “Max. Open Period” option.

The setting is stored.

The input unit returns to the menu option “Settings S1 Max. Open Period”. You can now configure other settings or return to the standard mode display.

Confirmation screen displaying “Stored,” indicating the Maximum Open Period setting has been saved.
Settings menu returning to the “Max. Open Period” option after the setting is stored.