Resolution
Follow these steps to retrieve Audits from the Keypad:
- From the Main Menu, select System.
- Select the applicable System from the Systems list.
- Click the PC Link icon in the top-right menu.
- Verify the COM port or select a different port from the drop-down menu.
- Click Audit from the left-hand column.
- Connect the Keypad to the PC:
- Plug the 700 Series USB Dongle into the PC.
- Connect the USB end of the cable to the dongle.
- Connect the mini-USB end to the Keypad.
- Enter a valid User ID and combination on the Keypad.
- Use the arrow buttons to navigate the Main Menu and select PC Link. The LED will turn red.
- In the PC Link window, select the User ID and enter the corresponding combination used on the Keypad.
- Click the Receive icon. A progress bar will appear. The Keypad will beep three times and flash a green LED when complete.
- Navigate through the transactional data displayed in the software client.
- If needed, click the Generate icon to open a report window. Use the icons to Print, Enlarge, or Save the report.
|