Paxos - Setting the Content of the Battery Compartment

In principle, the locking system control automatically recognizes whether the system is connected to an external voltage source (possible only with option I/O-Box), if the battery compartment is empty or if batteries or a rechargeable battery pack have been inserted.

If, for some reason, the battery compartment content is not properly recognized (see table below), you can change the type of power supply via the setting “Power”. It is essential to note and follow the following instructions.

Battery Compartment Display Messages

Display Power Supply Type
Display screen showing “Bat.Comp. content: Battery” with a battery icon, indicating standard batteries are installed.
Display says Bat.Comp.content Battery with icon of battery

Batteries are inserted in the battery compartment. 

If the locking system is connected to an external voltage source, the batteries serve as backup in case of power failure. No charging current flows.

Display screen showing “Bat.Comp. content: Rechargeables” with a rechargeable battery icon, indicating a rechargeable battery pack is installed.
Display says Bat.Comp.content Recharables with icon of battery
A rechargeable battery pack is inserted in the battery compartment. If the locking system is connected to an external voltage source, the batteries serve only as backup in case of power failure. During operation, the battery pack is recharged constantly. The * symbol in the display
indicates the charging process.
Display screen showing “Bat.Comp. content: Empty” with an empty battery icon, indicating no batteries are present.
Display says: Bat.Comp.content Empty with image of empty battery
The battery compartment is empty.


Danger of Explosion

Alkaline and lithium batteries may be not charged because they can explode during charging and thus injure persons or damage property. Therefore, never set the supply to “Battery” when alkaline or lithium batteries are inserted in the battery compartment and the system is connected to an external power supply, since if set to “Rechargeable battery” a charging current flows to the battery compartment during operation.


Authorization & Requirements

  • Authorization: Master Code “MA1”
  • Requirement: System status “Unlocked” (door locks and door bolt open)

Procedure: Correcting the Battery Compartment Content

To correct the battery compartment content, proceed as follows:

1. Wake up display (if necessary) and access menu.

status “Unlocked” with date and time, indicating the lock is ready for configuration.
Wake up display: Enter
Wake up display

2. Select and confirm the menu option “Settings”.

Menu screen highlighting the “Settings” option on the Paxos lock display.
Menu Settings : Enter

3. Select and confirm menu option “Settings Input Unit”.

Settings menu showing “Input Unit” selected on the lock display.

4. Select and confirm menu option “Input unit bat.comp. content”.

Input Unit menu showing “Bat.Comp. content” selected on the display.

5. Enter and confirm Master Code of lock 1.

Lock display prompting for “Code Lock 1,” indicating entry of the master code is required.
Lock display showing masked master code entry for authorization.

Batteries inserted in the battery compartment 

Rechargeable battery pack inserted in the battery compartment

Battery compartment empty

6. Set battery compartment content according to the actual situation on the ground and confirm.
Note: It is essential here to observe the information provided at the start of this section.

Selection screen displaying battery compartment options: Battery, Rechargeables, and Empty.

The setting is stored.

The input unit returns to the menu option “Input Unit bat.comp content”. You can now configure other settings or return to the standard mode display.