Reading-out audits - Audit via Combi B 90 PC Software

Updated Feb 20, 2026

Reading-out audits - Audit via Combi B 90 PC Software

Time Settings and Battery Change

  • If, during a battery change, the lock remains without power for more than 1 minute, the time must be set again.

  • If the time is not reset:

    • No real time is saved in the audit.

    • Only a calculated relative time is stored.

  • If the lock clock is not set manually or automatically using one of the time functions:

    • No real time will be saved in the audit.

    • A relative time will be shown in the audit read-out.

Audit Memory – General Information

  • The audit memory is the event memory of the lock.

  • It stores approximately 960 events related to:

    • Configuration

    • Operation

Reading Out the Audit

  1. Click Start reading-out.
    Click Start reading-out.

  2. The audit is generated.

    Audit generated

  3. Events are listed according to:

    • Date

    • Time

    • User ID

Audit Columns – Explanation

  • Relative Time

    • Displayed when the lock time does not match the PC time.

    • Calculated based on the PC time settings.

    • Only valid from the last battery change.

    • Events before the last battery change have no time stamp.

  • Date

    • Events are listed in chronological order.

    • Starts with the oldest date and ends with the most recent date.

  • Time

    • Shows the time at which each event occurred.

  • User ID

    • Indicates which user performed the action.

  • Events

    • Describes the action that occurred.

Audit Events – Description Table

Event Description
Opened The lock is opened.
OpenedByKey The lock was opened with the emergency key.
CodeOK The correct code was entered, but the lock was not opened.
CodeOkOvStart The correct code was entered to start the Opening Delay.
CodeOKDuressAlarm The Duress Code was entered.
DualCodeFirstOk The first code was entered correctly.
DualCodeSecondOk The second code was entered correctly.
CodeWrong A wrong code was entered to open the lock.
IdWrong A user tried to open the lock with no activated or existing ID.
Closed The lock is closed.
AhkNeutralizedP9 The pick-up contact message has been reset.
AhkSet The pick-up contact has been set.
AuditOutput The audit was read-out.
BlockingPeriod1 Blocking period 1 (1 minute blocking time was triggered).
BlockingPeriod2 Blocking period 2 (2 minutes blocking time was triggered).
BlockingPeriod4 Blocking period 4 (4 minutes blocking time was triggered)
BlockingPeriod8 Blocking period 8 (8 minutes blocking time was triggered)
BlockingPeriod16 Blocking period 16 (16 minutes blocking time was triggered).
CodeStateRequestedP6 The code status request was activated (P6).
ConfirmationWindowOpeningDelayP2 The Opening Delay was changed (P2).
DualCodeDisabled The Dual Mode was disabled (P7).
DualCodeEnabled The Dual Mode was enabled (P7).
ExternalPowerAvailable External power available.
ExternalPowerNotAvailable No external power available.
PcCommunicationP1 The PC communication mode was activated on the lock (P1).
DuressAlarmDisabled The Duress Alarm was disabled (P8).
DuressAlarmEnabled The Duress Alarm was enabled (P8).
UnderVoltage Battery low voltage.
MasterCreatedUserP3 The master created a user (P3).
MasterActivatedOrDeactivatedUserP4 The master activated or deactivated a user (P4)
MasterDeletedUserP5 The master deleted a user (P5).
MasterChangedPermission The master changed the authorization of the manager.
TimeWasChangedORSet The time was changed or set.
ManagerCreatedUserP3 The manager created a user (P3).
ManagerActivatedOrDeactivatedUserP4 The manager activated or deactivated a user (P4).
ManagerDeletedUserP5 The manager deleted a user (P5).
ManagerChangedTimeDelay The manager changed an Opening Delay.
ManagerLocksDualCode The manager deactivated the Dual Mode.
TimeDelayAbort Cancellation of Opening Delay.

Applies To

Combi B 90