Set Combination in LA GARD Mechanical Combination Group 1, Group 2 & Group 2M Locks

Updated Feb 20, 2026

How to Set Combination in LA GARD Mechanical Combination Group 1, Group 2 & Group 2M Locks?

To change the combination, you will need to: 

  • Know the existing combination
  • Have a LA GARD change key (P/N 1307).
Figure 1: LA GARD Mechanical Combination Group 1, Group 2 & Group 2M Locks

CAUTION: When selecting a combination, choose a three number sequence from 0 - 99. NEVER select numbers 0 to 20 as the LAST NUMBER of the combination. This is the “Forbidden Zone” and can cause the lock to malfunction. For security purposes, do not select a combination from personal data such as birth date, phone number, etc. You also should not share the combination. It is a secret.

Steps to Set Combination

  1. Dial the existing combination using the CHANGING Index. (Figure 1.)
  2. STOP the dial on the third number of the combination.
  3. Insert the change key into the change key hole. (Figure 2.)

NOTE: If the change key does not go in easily, the wheels are not aligned. Repeat steps 1 - 3.

  1. Turn the change key to the RIGHT (CW) one-quarter turn until the key stops. (Figure 2.) Leave the change key in the lock while setting the new combination.
  2. Next turn the dial to the LEFT (CCW) at least four complete rotations to clear the lock. The lock is now ready to accept the new combination.
    CAUTION: Do not spin the dial to clear the lock.
  3. Set the new combination using the CHANGING Index: EXAMPLE COMBINATION: 10-20-30
Turn left 4 times
Turn the dial LEFT (CCW) passing the first number in the combination (10) three times. Then stop exactly on the number “10” the fourth time.
Turn right 3 times
Turn the dial RIGHT (CW) passing the next number in the combination (20) two times. Then stop exactly on the number “20” the third time.
Turn left 2 times
Turn the dial LEFT (CCW) passing the last number in the combination (30) one time. Then stop exactly on the number “30” the second time.
  1. Hold the Dial to prevent movement and turn the change key to the LEFT (CCW) one quarter turn.
  2. Remove the change key. The new combination is now set.
  3. ALWAYS perform the combination test with the safe door open! Test the new combination several times using the opening procedure below.

Applies To

LA GARD Mechanical Combination Group 1, Group 2 & Group 2M Locks