Paxos - Operating Errors

Updated Feb 21, 2026

Error Messages / Troubleshooting Paxos

In the following table, you will find error messages that may appear while operating the locking system as well as information on the locking system component(s) affected by the fault, the cause of the fault, as well as advice on how to eliminate the fault.

We generally recommend that the locking system should be checked by an authorized business partner when errors occur.

Error 
Number

Description
 
Details/Remedy
 

10xx

Problem with the addressing sequence

1000

– System was addressed
– Sequence of the components was modified
– New addressing necessary
 

11xx

Addressing Problems

1100

– One component could not be found when addressing

 
– Check wiring and correct if necessary
– Check fuses in input unit and replace if necessary
– Re-address system

12xx

Communication problem

1200 -
1201




 

– One or more components do not answer




 
– Check wiring and correct if necessary
– Check fuses in input unit and replace if necessary
– Disconnect batteries and externals power supply for 10 minutes
– Restart system

1220


 

– See also general error 1200 -> concerns particularly the I/O-Box

 
– Check wiring to I/O-Box and correct if necessary
– Re-address system
– Disconnect Bus and power supply to I/O-Box and reconnect

1230



 

– See also general error 1200 -> concerns particularly the IP-Box


 
– Check wiring to IP-Box and correct if necessary
– Re-address system
– Disconnect Bus and power supply to IP-Box and reconnect

13xx


 

– General locking bolt error


 
– Check bolt work and movement of locking bolt
– The maximum force of the lock of 30N may not be exceeded
– Check locking bolt path

1300




 

– The time of 8 seconds was exceeded when closing



 
– Locking bolt jammed -> check
– Limit switch are not detected
– Check closing time with removed lock
– If possible and necessary, limit bolt path with adjusting screw
– Replace lock if necessary

1310




 

– The time of 8 seconds was exceeded when opening



 
– Locking bolt jammed -> check
– Limit switch are not detected
– Check opening time with removed lock
– If possible and necessary, limit bolt path with adjusting screw
– Replace lock if necessary

1320

 

– Lock control error

 
– Try again
– Disconnect system from all supplies and restart
– Immediately replace lock

1330

 

– Limit switch(es) was/were not detected

 
– Lock is/was open and was possibly opened via the Service menu
– Replace lock if necessary

1340


 

– Error of the motor when closing


 
– Try again
– Check for correct movement locking bolt and bolt work
– Replace lock if necessary

1350


 

– Error of the motor when closing


 
– Try again
– Check for correct movement locking bolt and bolt work
– Replace lock if necessary

14xx-15xx

Problems with the lock bolt contacts

1400

– Error of the lock bolt contacts when opening - See 1310
 

1500

– Error of the lock bolt contacts when closing – See 1300

16xx

Problems with the door bolt contacts

1620

– In secured status the status of the door bolt contacts have changed unexpectedly – Check wiring and door bolt contacts
 

17xx

Redundancy problem

1700-1701

– Problems with redundant system components – The redundant components have reacted and answered differently
– If time functions are affected: Delete last time locking and reenter time locking
– If code functions are affected: Delete appropriate code(s) and reenter code(s)
– If problem cannot be resolved, reset system.

18xx,
19xx

Problem with batteries/rechargeable battery pack

1800

– Batteries/rechargeable battery pack discharged
 
– Charge of the Batteries/rechargeable battery pack is low
– Replace if necessary

1900

– Batteries/rechargeable battery pack are flat – Charge of the Batteries/rechargeable battery pack is very low
– Replace if necessary

21xx

Addressing problems

2101

– Addressing problem Bus A

 
– Address(es) could not be saved on Bus A
– Wait (10 seconds), then try again
– Check wiring

2102

– Addressing problem Bus B  – Address(es) could not be saved on Bus B

2103

-(MIH_ERROR_CAUSE_ADDRESSING__TIMEOUT = 2103)
– Timeout during Addressing
 
– Addressing not possible
– Check wiring
– Check fuses in input unit
– Replace input unit

2104

– General addressing problem


 
– Addressing not possible
– Check wiring
– Check fuses in input unit
– Replace input unit

2105

– Wrong firmware version of installed system component

 
– Check compatibility of the firmware version of the installed system components, update firmware or replace system components if necessary.

2106

– Max. number of locks on Bus exceeded
 
– Reduce number of locks on Bus (max. 11 locks per system)

2107

– Max. number of Bus components exceeded


 
– By adding a lock, the max number of system components is exceeded (max. 12 per system). Reduce number of components
on Bus

2108

– Max. number of input units on Bus exceeded
 
– Reduce number of input units on Bus (max. 3 input units per system)

2109

– Max. number of components on Bus exceeded


 
– By adding an input unit the max. number of system components is exceeded (max. 12 per system). Reduce number of components on Bus

2110

– Max. number I/O / IP-Boxes on Bus exceeded

 
– Reduce number of I/O / IP-Boxes on Bus (max. 3 I/O-Boxes per system or max. 1 IP-Box per system)

2111

– Max. number of components on Bus exceeded


 
– By adding an I/O or IP-Box the max. number of system components is exceeded (max. 12 per system). Reduce number of components on Bus.

2113 -
2117

– Addressing error
 
– Max. number of components on Bus exceeded

22xx

Flash memory problem

2200

– Flash memory Checksum error
 
– Disconnect system from all supplies and restart
– If problem cannot be resolved, replace lock

23xx

Reset Problem

23xx

– Error when resetting

 
– Disconnect system from all supplies, restart and reset again
– If problem cannot be resolved, replace lock

24xx

Problems with the time synchronization of the redundant lock parts

2400

– Redundant lock parts have a time deviation of more than three minutes

 
– Set actual time of day
– If the error occurs again, disconnect system from all supplies and restart
– If problem cannot be resolved, replace lock 1

25xx

Various Problem

2501

– Battery code was not entered and red button on I/O / IP-Box was pressed – Possible manipulation attempts to remove time lock

2502

– Red button was pressed on a not addressed I/O / IP-Box – New addressing necessary

Notes on Troubleshooting

Please note the following information when dealing with faults:

  • A fault does not cause a total system failure, since all electronic components in the secured area are redundant (present twice) and the part that is still working automatically takes over the functions.
  • It is important to remedy any signaled errors immediately. In the event of a fault, always write down the entire fault message (see section 8.1 "Error messages / Troubleshooting") and immediately contact your business partner or your safe provider (address and telephone number are provided on page 2 of this manual). Inform the business partner even if the locking system continues to operate normally after there has been an error message.
  • If existing faults are not remedied, the opening function of the locks is automatically disabled after the tenth consecutive error message. This disabling can only be cancelled by the business partner. It prevents a total system failure that could result in the container being permanently locked.

Customer Service

Should you encounter any malfunction or operating problems, please contact your authorized
business partner or your safe provider.