909 Surface and Flush Mount Rocker Switches Installation Instructions

Updated Mar 26, 2026

909 Surface and Flush Mount Rocker Switches Installation Instructions

909 rocker switches support both surface and flush mounting for versatile installation in access control systems. These SPDT switches feature momentary action (convertible to maintained), NO/NC contacts rated at 10A @ 24VDC, and a standard beige plastic finish. The instructions below cover both mounting methods with wiring diagrams.
 

Switch Mode Switch Configuration Switch Rating Standard Finish
Momentary Action* SPDT N/O or N/C 10A @250V Beige (Plastic)

909 SURFACE MOUNT INSTRUCTIONS

1. Remove decorative bezel around switch.

Optional: * To convert the momentary switch provided to maintained switch mode, carefully remove the spring located under the rocker switch with a small screwdriver or pliers.

2. Mount switch base in desired location.

3. Connect wires under appropriate terminals (Fig. 1).

4. Replace decorative bezel.

RCI 909 surface mount rocker switch showing bezel removal, wire connections (C, NO, NC), and screwdriver conversion from momentary to maintained action
Figure 1

909 FLUSH MOUNT INSTRUCTIONS

1. Pry off decorative bezel around switch and remove toggle. 

2. Cut a 2-1/4” x 1-1/4” hole in the drywall. 

3. Connect wires under appropriate terminals (Fig. 2).

4. Insert switch into hole. Tighten the two metal slot screws, until switch is secure.

5. Replace toggle and decorative bezel.

"RCI 909 flush mount rocker switch installation showing bezel removal, 2½ x 1½ inch wall cutout, wire connections, and bezel replacement
Figure 2

NOTE: Specifications are subject to change without notice.
N/C - Normally Closed, N/O - Normally Open, C - Common
* Surface mounted switches only may be converted to Maintained Switch Mode.