What is the Patient Safety Lever (SPSL)?

Updated Mar 24, 2026

Question

What is the Patient Safety Lever (SPSL)?

Answer

The SPSL Series consists of both a mortise lock and a cylindrical lock. The SPSL meets the needs of resisting ligature engagement on the lock trim while providing patients and staff with easy-to operate hardware. The patented design meets the intent of ADA by eliminating the operational requirement “pinch & grasp” motion.

Additional Information

Please see below for the frequently asked questions about the Behavioral Health FAQs. If you would like a PDF copy of this file, please click here. For specification information or more information on the Behavioral Health, please see the catalog.

SPSL Lock
Patient Safety Lever Lock

Diagram of a stainless-steel door lockset with labeled components. The lock features a cylindrical SFIC core at the top that “accepts any SFIC core,” solid stainless-steel construction, and high-security Torx fasteners on the faceplate. The trim includes a non-moving conical exterior and a free-moving, bi-directional lever handle with a low profile and 1-3/4 inch protrusion. The latch and rectangular faceplate are visible on the door edge. Certification icons appear along the bottom, including accessibility, UL Listed, ANSI, and BHMA Certified.