Simplex 8100 Templates and Instructions

Updated Sep 10, 2026

Simplex 8100 - Mortise Templates and Instructions

Simplex 8100

Templates

Template ID Description Last Updated
PKG2633 Simplex 8100 Drilling Template 01/2012

Instructions

Document ID Description Last Updated
PKG2589 Simplex 8100 Installation Instructions 01/2012
KAA1159 Simplex LP1000/8100 Changing the Code 12/2007
PKG3216E Reset Unknown/Lost Simplex Combination Code 12/2010
PKG3216E_Spanish Reset Unknown/Lost Simplex Combination Code Spanish 03/2015
PKG3216E_French Reset Unknown/Lost Simplex Combination Code French 03/2015

Specifications

Product Details

  • Access Control: Mechanical pushbutton lock—eliminates problems and costs associated with issuing, controlling, and collecting keys and cards. Provides exterior access by combination, while allowing free egress.
  • No Battery: Fully mechanical lock eliminates the material and labor expense of battery replacements
  • Locking Device:
    • Mortise with 1" (25mm) deadbolt, 3/4" (19mm) two-piece anti-friction latch
    • Mortise with 3/4" (19mm) two-piece anti-friction latch
  • Number of Codes: Single access code—one easy-to-manage code for all users
  • Programming: Lock is easily programmed via keypad without removing lock from the door
  • Handing: Factory-handed; not field reversible
  • Operation Mode:
    • Pushbutton Access
    • Passage (select models)—allows access without using the lock entry code. Feature activated from the inside with a thumbturn or key (included with all passage feature models).
    • Deadbolt (select models)—added security of 1" deadbolt. Access permitted by combination or key override.
    • Lockout (all models)—disables the lock from the inside so that the entry codes cannot be used to gain access. Access is permitted using key override.
  • Economical: A cost effective access control solution.

Technical Details

  • Construction: Cast front housing; unified trim plate; fixed ADA-compliant levers
  • Numeric Keypad: Vandal resistant, solid metal pushbuttons
  • Backset: 2 3/4" (70 mm)
  • Latch: 3/4" (19 mm) two-piece anti-friction latch; 1" (25 mm) optional deadbolt
  • Minimum Stile Recommended: 5" (127 mm)
  • Strike: 4 7/8" (124 mm) L x 1 1/4" (32 mm) W x 1/4" (6 mm) D Deadbolt/Latch mortise strike plate
  • Key Override:
    • Interchangeable Cores: Small format—Best and equivalents (6 or 7-pin length); core not included
    • Removable Cores: Large format—Medeco/ASSA/Yale/Abloy (5 or 6-pin length), Corbin Russwin, Schlage, and Sargent; core not included
  • Door Preparation: Easily installs on wood or metal doors. Standard (86) mortise preparation
  • Door Thickness: 1 3/4" (44 mm) to 2 1/4" (57 mm)
  • Accessibility Standard: Americans with Disabilities Act (ADA); fixed ADA-compliant levers
  • Durability: Weather resistant
  • Fire Rating: 3-hour UL/ULC fire rating for "A" labeled doors
  • Warranty: 3-year warranty
  • Finishes:
    • Standard:
      • Antique Brass 05 (609)
      • Satin Chrome 26D (626)
    • Optional:
      • Bright Chrome 026 (625)
      • Bright Brass 03 (605)

Care and Maintenance

Important Information

 Before using any cleaning or disinfecting product, please take the following steps: 

• Only use products that are recommended for the intended surfaces - particularly on plastic surfaces, especially when using alcohol-based cleaning agents 

• Always visit the website of the cleaning product manufacturer for a list of specific properties or instruction guidelines 

• Pay special attention to plastic surfaces with a gloss finish as these may be more susceptible to scratching or tarnishing 

• We strongly recommend first testing any new product on a small surface and waiting for a period of 4 hours to ensure there is no detrimental effect

Extreme Conditions 

For locks with Ocean Front finish, we also recommend regular cleaning and waxing. 

• On a weekly basis, remove salt from the lock using a damp cloth. This is for area subject to salt mist. 

• We recommend cleaning, polishing and waxing locks using a suitable polisher agent every 6 months and this should be adjusted according to the severity of the environment.